Choose Country & language

Mongolia
Algeria Argentina Armenia Australia Austria Azerbaijan Bahrain Bangladesh Belarus Belgium Bolivia Brazil Bulgaria Canada Chile China Colombia Croatia Cyprus Czech Republic Denmark Dominican Republic Ecuador Egypt Estonia Finland France Georgia Germany Greece Hungary India Indonesia Iran Iraq Ireland Island Italy Jordan Kazakhstan Kenya Korea Kuwait Latvia Lebanon Libya Lithuania Luxembourg Malaysia Malta Mexico Mongolia Morocco Netherlands New Zealand Nigeria Norway Oman Pakistan Paraguay Peru Philippines Poland Portugal Qatar Romania Russian Federation Saudi Arabia Serbia Singapore Slovakia Slovenia South Africa Spain Sweden Switzerland Syria Thailand Tunisia Turkey Ukraine United Arab Emirates United Kingdom United States Uruguay Uzbekistan Venezuela Viet Nam Yemen

Item no: UP210

ENDOMAT SELECT

Quantity:
  • Technical details
  • Documents & Films
  • Product group / field of application
Pump functionSuction or irrigation pump
Unit typeRoller pump
Power supply100 – 240 VAC
Width305 mm
Height110 mm
Depth260 mm
Weight4.7 kg
Line frequency50/60 Hz
Pressure regulated – Normal20 – 150 mmHg
Suction flow: Software license IBS® shaver100 – 300 ml/min
Suction flow: Software license URO (RES)100 – 1000 ml/min
Suction flow: Software license URO (CALCUSON)300 – 1000 ml/min
Suction flow: Software license HYS10…180 ml/min
Suction flow: Software license ART100…1000 ml/min
Certified toIEC 60601-1
Irrigation pressure in flow-controlled proceduresMax. 500 mmHg
Irrigation flow in flow-controlled proceduressoftware license SURG (LAP, THOR and PRO): 100-3500 ml/min, software license GI (GASTROENTEROLOGY): 100-1000 ml/min, Software license HNO / NEURO: 50 / 65 / 80 / 95 / 110 / 130 ml/min
Irrigation pressure in pressure-controlled procedures20 – 150 mmHg
Irrigation flow in pressure-controlled proceduresSoftware license HYS and URO: max. 600 ml/min, Software license SPINE: max. 600 ml/min, Software license ART: max. 2500 ml/min
Irrigation flow (ml/min)Accuracy (0…3500 ml/min): +/- 20 %; HYS, URO, SPINE: 200-400-600; ART: 1500-2000-2500; SURG: 100…2500 (Advanced: 100…3500); GI: 100...1000; ENT/NEURO: 50-65-80-95-110-130
Irrigation pressure (mmHg) max.Accuracy (up to 100 mmHg): +/- 10, HYS, URO, ART, SPINE: 20…150, LAP, GI: 100-300-500 (Advanced only)
BrandENDOMAT® SELECT
Unit communication SCBYes
SCB connection2
IP protection classIP21
Electrical protection classProtection class 1
Degree of safetyCF
Control via touch screenYes
Wipe disinfectionYes
System requirements for SCBSCB control NEO system with integrated SCB control NEO, Software Release 20090001-46 or higher
DisplayTFT screen
Socket for external systems1
Unit communication KS HIVE®No
Connection socket for footswitch1
Bottle stand includedNo
Power consumption72 VA
Operative procedureART, CYST, PCN, URS, RES, HYS, IBS, LAP, PRO, THOR, SPINE
Suction flow (ml/min)IBS® shaver: 100...300 ml/min
Electrical protection classI